dc-voltage | 12 |
---|---|
rated-current | 3.75 |
current-range | 0 ~ 3.75A |
rated-power | 45 |
ripple-noise | 120mVp-p |
voltage-adj-range | 10.8 ~ 13.2V |
voltage-tolerance | ±2.0% |
line-regulation | ±1.0% |
load-regulation | ±1.0% |
set-up-rise-time | 1000ms, 50ms, —-/12VDC/24VDC at full load; 1500ms,50ms,—-48VDC at full load |
hold-up-time | 1000ms, 50ms, —-/12VDC/24VDC at full load; 1500ms,50ms,—-48VDC at full load |
input-voltage-range | 18 ~ 36VDC (24VDC |
efficiency | 82% |
dc-current | 1.2, 2.5, 3.5, 3.5A/12VDC 2.5A/24VDC 1.2A/48VDC |
overload | 105% -160% rated output power Protection type :shut down, Re-power on after fault condition is removed |
over-voltage | Protection type : Hiccup mode, recovery automatically after fault condition is removed 13.8~ 16.2V/10%load |
working-temp | '-10 ~ +60℃ (Refer to output load derating curve),20~90%RH non-condensing |
working-humidity | 20 ~ 95% RH non-condensing |
storage-temp-humidity | '-20 ~ +85℃, 10 ~ 95% RH |
temp-coefficient | ±0.05%/℃ (0 ~ 50℃) |
vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
safety-standards | EN60950-1 CB approved by TUV |
with-stand-voltage | I/P-O/P:1.5KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC |
isolation-resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH |
emi-conduction-radiation | Compliance to EN55022(CISPR22) CLASS B |
emc-immunity | Compliance to EN61000-4-2, 3, 4, 6, 8 EN55024, EN61000-6-1, light industry level, criteria A |
mtbf | 329.3Khrs min. MIL-HDBK-217F (25℃) |
dimension | 127*76*30mm (L*W*H) |
packing | 0.19Kg;72pcs/15.6Kg/1.35CUFT |