| dc-voltage |
24
|
| rated-current |
1.5
|
| current-range |
0 ~ 1.5A
|
| input-voltage-range |
85 ~ 264VAC 120 ~ 370VDC
|
| rated-power |
36
|
| working-temp |
'-20 ~ +60℃ (Refer to "Derating Curve")
|
| storage-temp-humidity |
'-40 ~ +85℃, 10 ~ 95% RH
|
| ripple-noise |
150mVp-p
|
| voltage-adj-range |
21.6 ~ 26.4V
|
| voltage-tolerance |
±1.0%
|
| emc-emission |
Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3
|
| line-regulation |
±1.0%
|
| load-regulation |
±1.0%
|
| hold-up-time |
100ms/230VAC 21ms/115VAC at full load
|
| working-humidity |
20 ~ 90% RH non-condensing
|
| efficiency |
83%
|
| frequency-range |
47 ~ 63Hz
|
| ac-current |
0.88A/115VAC 0.48A/230VAC
|
| inrush-current |
COLD START 15A/115VAC 30A/230VAC
|
| isolation-resistance |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
|
| safety-standards |
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
|
| overload |
105 ~ 160% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
| vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
|
| over-voltage |
Protection type : Shut down o/p voltage, re-power on to recover 27.6 ~ 32.4V
|
| temp-coefficient |
±0.03%/℃ (0 ~ 50℃)
|
| set-up-rise-time |
100ms, 30ms/230VAC 100ms, 30ms/115VAC at full load
|
| with-stand-voltage |
I/P-O/P:3KVAC
|
| emc-immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
|
| mtbf |
441.5K hrs min. MIL-HDBK-217F (25℃)
|
| dimension |
78*93*56mm (W*H*D)
|
| packing |
0.27Kg; 48pcs/14Kg/1.02CUFT
|
نقد و بررسیها