dc-voltage |
5
|
rated-current |
6.5
|
current-range |
0 ~ 6.5A
|
input-voltage-range |
88 ~ 264VAC 124 ~ 370VDC
|
rated-power |
32.5
|
working-temp |
'-20 ~ +60℃ (Refer to "Derating Curve")
|
storage-temp-humidity |
'-40 ~ +85℃, 10 ~ 95% RH
|
ripple-noise |
80mVp-p
|
voltage-adj-range |
4.75 ~ 5.5V
|
voltage-tolerance |
±2.0%
|
emc-emission |
Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3
|
line-regulation |
±1.0%
|
load-regulation |
±1.0%
|
hold-up-time |
100ms/230VAC 23ms/115VAC at full load
|
working-humidity |
20 ~ 90% RH non-condensing
|
efficiency |
76%
|
frequency-range |
47 ~ 63Hz
|
ac-current |
1.2A/115VAC 0.8A/230VAC
|
inrush-current |
COLD START 18A/115VAC 36A/230VAC
|
isolation-resistance |
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
|
safety-standards |
UL60950-1, TUV EN60950-1 approved, design refer to EN50178
|
overload |
105 ~ 160% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
|
over-voltage |
Protection type : Shut down o/p voltage, re-power on to recover 5.75 ~ 6.9V
|
temp-coefficient |
±0.03%/℃ (0 ~ 50℃)
|
set-up-rise-time |
100ms, 30ms/230VAC 200ms, 30ms/115VAC at full load
|
with-stand-voltage |
I/P-O/P:3KVAC
|
emc-immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
|
mtbf |
216.2K hrs min. MIL-HDBK-217F (25℃)
|
dimension |
78*93*56mm (W*H*D)
|
packing |
0.3Kg; 48pcs/15.4Kg/1.02CUFT
|
نقد و بررسیها
هنوز بررسیای ثبت نشده است.