توضیحات
| dc-voltage | 27.6 |
|---|---|
| rated-current | 1.8 |
| current-range | 0 ~ 1.8A |
| PEAK 5S | 2.2A |
| rated-power | 49.7 |
| ripple-noise | 200mVp-p |
| voltage-adj-range | '+15,-5% |
| voltage-tolerance | ±1.0% |
| line-regulation | ±1.0% |
| load-regulation | ±1.0% |
| set-up-rise-time | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load |
| hold-up-time | 50ms/230VAC 16ms/115VAC at full load |
| input-voltage-range | 85 ~ 264VAC 120 ~ 370VDC |
| frequency-range | 47 ~ 63Hz |
| efficiency | 85% |
| ac-current | 1.1A/115VAC 0.65A/230VAC |
| inrush-current | COLD START 45A |
| LEAKAGE CURRENT | <2mA / 240VAC |
| temp-compensation | By NTC (not provide with the power supply) |
| output-voltage-sensor | L=output voltage +0.2 ~ 0.7V(AC OK); L=0V(AC Fail) |
| overload | Protection type : Hiccup mode, recovers automatically after fault condition is removed 2.2 ~ 2.9A rated output power |
| over-voltage | Protection type : Shut down o/p voltage, re-power on to recover 33.1 ~ 38.5V |
| working-temp | '-20 ~ +60℃(Refer to output load derating curve) |
| working-humidity | 20 ~ 90% RH non-condensing |
| storage-temp-humidity | '-40 ~ +85℃, 10 ~ 95% RH |
| temp-coefficient | ±0.03%/℃(0 ~ 45℃) |
| vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
| safety-standards | UL60950-1, CB(IEC60950-1) approved |
| with-stand-voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
| isolation-resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH |
| emc-emission | Compliance to EN55022 (CISPR22) Class B,EN61000-3-2,3 |
| emc-immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A |
| mtbf | 495.7K hrs min. MIL-HDBK-217F (25℃) |
| dimension | 129*98*38mm (L*W*H) |
| packing | 0.45Kg; 30pcs/14.5Kg/0.95CUFT |
نقد و بررسیها