| dc-voltage |
48
|
| rated-current |
3.2
|
| rated-power |
153.6
|
| ripple-noise |
200mVp-p
|
| over-voltage |
Protection type : Shut down o/p voltage, re-power on to recover52 ~ 63V
|
| voltage-tolerance |
±5.0%
|
| line-regulation |
±1.0%
|
| load-regulation |
±2.0%
|
| voltage-adj-range |
LPV-150: 180 ~ 305VAC 254 ~ 431VDC; LPVL-150: 90~132VAC 254 ~ 370VDC
|
| set-up-rise-time |
LPV-150: 500ms, 50ms / 230VAC 500ms, 50ms / 277VAC; LPVL-150: 1500ms, 50ms / 115VAC
|
| hold-up-time |
LPV-150: 18ms/230VAC 20ms/277VAC at full load; LPVL-150: 10ms/115VAC at full load
|
| frequency-range |
47 ~ 63Hz
|
| efficiency |
90%
|
| ac-current |
LPV-150: 1.7A/230VAC 1.5A/277VAC; LPVL-150: 3.0A/115VAC
|
| inrush-current |
COLD START 60A(twidth=900μs measured at 50% Ipeak) at 230VAC
|
| input-voltage-range |
LPV-150: 180 ~ 305VAC 254 ~ 431VDC; LPVL-150: 90~132VAC 254 ~ 370VDC
|
| max-no-of-psus-on-16a-circ |
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
|
| working-temp |
'-25 ~ +65℃(Refer to "Derating Curve")
|
| working-humidity |
20 ~ 90% RH non-condensing
|
| storage-temp-humidity |
'-40 ~ +80℃, 10 ~ 95% RH
|
| temp-coefficient |
±0.03%/℃(0 ~ 40℃for LPV-150-12,15 and LPVL-150-12,24;0~50℃for LPV-150-24,36,48)
|
| vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
| with-stand-voltage |
I/P-O/P:3KVAC
|
| isolation-resistance |
I/P-O/P:>100M Ohms / 500VDC / 25Ž/ 70% RH
|
| emc-emission |
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A, EN61000-3-3
|
| emc-immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A
|
| mtbf |
703Khrs min. MIL-HDBK-217F (25℃)
|
| dimension |
191*63*37.5mm (L*W*H)
|
| packing |
LPV-150: 0.74Kg;20pcs/15.8Kg/0.95CUFT; LPVL-150: 0.85Kg;20pcs/17Kg/0.95CUFT
|
| leakage-current |
LPV-150: 0.25mA / 240VAC LPVL-150:0.25mA / 120VAC
|
| safety-standards |
UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1
|