DC VOLTAGE |
-15, -5, 15, 5, CH1:5V CH2:15V CH3:-5V CH4:-15V
|
RATED CURRENT |
CH1:5A CH2:2A CH3:0.5A CH4:0.5A
|
CURRENT RANGE |
CH1:0.5 ~ 8A
CH2:0.2 ~ 3A
CH3:0 ~ 1A
CH4:0 ~ 1A
|
INPUT VOLTAGE RANGE |
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
|
RATED POWER |
65
|
WORKING TEMP |
-25 ~ +70℃ (Refer to "Derating Curve")
|
STORAGE TEMP HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH
|
RIPPLE & NOISE |
CH1:80mVp-p CH2:120mVp-p CH3:80mVp-p CH4:80mVp-p
|
VOLTAGE ADJ.RANGE |
CH1: 4.75 ~ 5.5V
|
VOLTAGE TOLERANCE |
CH1:±2.0% CH2:+10,-4% CH3:±5.0% CH4:±5.0%
|
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
|
LINE REGULATION |
CH1:±0.5% CH2:±1.5% CH3:±0.5% CH4:±0.5%
|
LOAD REGULATION |
CH1:±0.5% CH2:±4.0% CH3:±1.0% CH4:±1.0%
|
HOLD UP TIME |
60ms/230VAC 14ms/115VAC at full load
|
WORKING HUMIDITY |
20 ~ 90% RH non-condensing
|
EFFICIENCY |
76%
|
FREQUENCY RANGE |
47 ~ 63Hz
|
AC CURRENT |
2A/115VAC 1.2A/230VAC
|
INRUSH CURRENT |
COLD START 40A/230VAC
|
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
|
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved
|
LEAKAGE CURRENT |
2mA in 240VAC
|
OVERLOAD |
110 ~ 150% rated output power
|
VIBRATION |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
OVER VOLTAGE |
CH1: 5.75 ~ 6.75V
|
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃)on +5V output
|
SET UP, RISE TIME |
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
|
WITH STAND VOLTAGE |
I/P-O/P:3KVAC, I/P-FG:2KVAC, O/P-FG:0.5KVAC
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
|
MTBF |
245.5Khrs min. MIL-HDBK-217F (25℃)
|
DIMENSION |
129*98*38mm (L*W*H)
|
PACKING |
0.44Kg; 30pcs/13.2Kg/0.72CUFT
|