| dc-voltage |
'-12, 12, 24, 5, CH1:5V CH2:12V CH3:24V CH4:-12V
|
| rated-current |
CH1:4A CH2:1.5A CH3:1A CH4:0.5A
|
| CURRENT RANGE |
CH1:0.5 ~ 8A CH2:0.2 ~ 3A CH3:0.1 ~ 1.5A CH4:0 ~ 1A
|
| input-voltage-range |
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
|
| rated-power |
68
|
| working-temp |
'-25 ~ +70℃ (Refer to "Derating Curve")
|
| storage-temp-humidity |
'-40 ~ +85℃, 10 ~ 95% RH
|
| ripple-noise |
CH1:80mVp-p CH2:120mVp-p CH3:180mVp-p CH4:80mVp-p
|
| voltage-adj-range |
CH1: 4.75 ~ 5.5V
|
| voltage-tolerance |
CH1:±2.0% CH2:±6.0% CH3:±8.0% CH4:±5.0%
|
| emc-emission |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
|
| line-regulation |
CH1:±0.5% CH2:±1.5% CH3:±2.0% CH4:±0.5%
|
| load-regulation |
CH1:±0.5% CH2:±3.0% CH3:±5.0% CH4:±1.0%
|
| hold-up-time |
60ms/230VAC 14ms/115VAC at full load
|
| working-humidity |
20 ~ 90% RH non-condensing
|
| efficiency |
78%
|
| frequency-range |
47 ~ 63Hz
|
| ac-current |
2A/115VAC 1.2A/230VAC
|
| inrush-current |
COLD START 40A/230VAC
|
| isolation-resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
|
| safety-standards |
UL60950-1, TUV EN60950-1 approved
|
| leakage-current |
2mA in 240VAC
|
| overload |
110 ~ 150% rated output power
|
| vibration |
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
|
| over-voltage |
CH1: 5.75 ~ 6.75V
|
| temp-coefficient |
±0.03%/℃ (0 ~ 50℃)on +5V output
|
| set-up-rise-time |
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
|
| with-stand-voltage |
I/P-O/P:3KVAC, I/P-FG:2KVAC, O/P-FG:0.5KVAC
|
| emc-immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
|
| mtbf |
245.5Khrs min. MIL-HDBK-217F (25℃)
|
| dimension |
129*98*38mm (L*W*H)
|
| packing |
0.44Kg; 30pcs/13.2Kg/0.72CUFT
|